XTLplus Control Panel
The XTLplus includes all the features and benefits of a residential or small commercial panel in a single small footprint.
The XTLplus Wireless Control Panel is packed with features, including Wi-Fi and Z-Wave on board. Onboard cellular communications can also be added with a 265 Cell Communicator. It also comes with all the features and benefits users need in a residential or small commercial panel: 99 Two-way, 900 MHz wireless zones, dual communication, support for up to eight two-way wireless key fobs or outputs, 200-event memory, 99 user codes, six areas, XTLplus Fast Programming and up to 140 Z-Wave devices.
- Residential
- Small business
- XTL+N Wireless Control Panel with Ethernet
- XTL+W Wireless Control Panel with Wi-Fi
- XTL+WZ Wireless Control Panel with Wi-Fi & Z-Wave®
- XTL+WZF Wireless Control Panel with Wi-Fi & Z-Wave®, 24-Hour Battery
California State Fire Marshall (CSFM)
SIA CP-01 False Alarm Reduction
ETL Listings
- ANSI/UL 985 - Control Units and Accessories, Household System Type (Residential Fire)
- ANSI/UL 1023 - Household Burglar Alarm System Units (Residential Burglary)
- ANSI/UL 1610 - Digital Alarm Communicator System (Commercial Burglary)
- ANSI/UL 1635 - Digital Alarm Communicator System Units (Commercial Burglary)
See XTL Series Compliance Note (LT-2516) and XT Series Compliance Note (LT-2515)
Product Resources
Specs & Guides
Version 254 | September 19, 2025
Panel Serial Number in Serial 3 Messages
This update allows you to enable Serial 3 messages to include the panel serial number. If enabled, the panel family and corresponding serial number appear at the end of each Serial 3 message, allowing the monitoring center to identify the correct system if two panels unintentionally use the same account numbers.
This update requires one of the following:
- SCS-VR Virtual Receiver
- SCS-1R Network Enabled Receiver with the SCS-150 Main Processor Card at firmware Version 108 (9/23/25).
To enable Serial 3 messages to include the XTL Series panel serial number, complete the following steps:
- At the keypad, enter 6653 (PROG) and select CMD to enter the programming menu.
- At SYSTEM REPORTS, go to SYSTEM INFORMATION.
- Select YES to enable Serial 3 messages to include the panel serial number. The default option is set to NO.
- Go to STOP to save programming.
To program Serial 3 messages to include the panel serial number on Dealer Admin, refer to TU-1484.
Holdup Zone Type
A new zone type called Holdup has been added to Zone Information. Holdup zones operate as silent panics and do not trigger bell actions, or audible or visual alerts on the keypad.
To program a zone type as Holdup at the keypad, complete the following steps:
- At the keypad, enter 6653 (PROG) and press CMD to enter the Programmer menu.
- At ZONE INFORMATION, go to ZONE TYPE.
- Press CMD to view additional zone types until you see HU (Holdup) as an option.
- Select HU (Holdup) as the zone type, then press CMD.
- Configure additional Zone Information options as needed.
- Go to STOP to save programming.
To program a zone type as Holdup in Dealer Admin, refer to TU-1484.