XTLtouch All-In-One
Let’s talk about “all-in-one” security systems. The reason they're popular with dealers is simplicity and speed of installation. But who wants to approach a blaring keypad to turn off the alarm siren? Unlike most all-in-ones with built-in sirens at the keypad, DMP's XTLtouch gives you the flexibility to install the siren where your customer wants it. For your customer's convenience, our enhanced all-in-one XTLtouch can support up to eight wireless sirens.
But we don't stop there — the XTLtouch is the industry's "enhanced all-in-one" for quite a few reasons.
The XTLtouch wireless control panel delivers a complete security solution with easy installation options: Table top or wall mount. Equipped with Entry Check-In Protection, up to eight external wireless sirens and up to seven additional wireless keypads, every XTLtouch unit comes standard with 99 zones of 900 MHz Two-Way wireless, Wi-Fi and built-in Z-Wave support. It also supports up to eight Two-Way Wireless key fobs or outputs and includes six areas, 200-event memory, 99 user codes and Fast Programming — all packed in an elegant, keypad-sized alarm panel.
- Residential
- Small business
- XTLtouch Wireless Control Panel with Wi-Fi and Z-Wave
- XTLtouch-LA Wireless Control Panel with Wi-Fi, Z-Wave and AT&T LTE Communication
- XTLtouch-LA-CAN Wireless Control Panel with Wi-Fi, Z-Wave and AT&T LTE Communication - Canada
- XTLtouchUSB-LA-CAN Wireless Control Panel for Canada with Micro-USB, Wi-Fi, Z-Wave and AT&T LTE Communication
- XTLtouchF-LA Wireless Control Panel with Wi-Fi, Z-Wave, 24 Hour battery, and AT&T LTE Communication
- XTLtouch-LV Wireless Control Panel with Wi-Fi, Z-Wave and Verizon LTE Communication
- XTLtouchF-LV Wireless Control Panel with Wi-Fi, Z-Wave, 24 Hour battery, and Verizon LTE Communication
- XTLtouchUSB-LV Wireless Control Panel with Micro-USB, Wi-Fi, Z-Wave and Verizon LTE Communication
- XTLtouchUSBF-LV Wireless Control Panel with Micro-USB, Wi-Fi, Z-Wave, 24 Hour battery, and Verizon LTE Communication
California State Fire Marshall (CSFM)
SIA CP-01 False Alarm Reduction
ETL Listings
- ANSI/UL 985 - Control Units and Accessories, Household System Type (Residential Fire)
- ANSI/UL 1023 - Household Burglar Alarm System Units (Residential Burglary)
- ANSI/UL 1610 - Digital Alarm Communicator System (Commercial Burglary)
See XTL Series Compliance Note (LT-2516) and XT Series Compliance Note (LT-2515)
Product Resources
Specs & Guides
Version 254 | September 19, 2025
Panel Serial Number in Serial 3 Messages
This update allows you to enable Serial 3 messages to include the panel serial number. If enabled, the panel family and corresponding serial number appear at the end of each Serial 3 message, allowing the monitoring center to identify the correct system if two panels unintentionally use the same account numbers.
This update requires one of the following:
- SCS-VR Virtual Receiver
- SCS-1R Network Enabled Receiver with the SCS-150 Main Processor Card at firmware Version 108 (9/23/25).
To enable Serial 3 messages to include the XTL Series panel serial number, complete the following steps:
- At the keypad, enter 6653 (PROG) and select CMD to enter the programming menu.
- At SYSTEM REPORTS, go to SYSTEM INFORMATION.
- Select YES to enable Serial 3 messages to include the panel serial number. The default option is set to NO.
- Go to STOP to save programming.
To program Serial 3 messages to include the panel serial number on Dealer Admin, refer to TU-1484.
Holdup Zone Type
A new zone type called Holdup has been added to Zone Information. Holdup zones operate as silent panics and do not trigger bell actions, or audible or visual alerts on the keypad.
To program a zone type as Holdup at the keypad, complete the following steps:
- At the keypad, enter 6653 (PROG) and press CMD to enter the Programmer menu.
- At ZONE INFORMATION, go to ZONE TYPE.
- Press CMD to view additional zone types until you see HU (Holdup) as an option.
- Select HU (Holdup) as the zone type, then press CMD.
- Configure additional Zone Information options as needed.
- Go to STOP to save programming.
To program a zone type as Holdup in Dealer Admin, refer to TU-1484.
Z-Wave Improvements
Previously the 738Z+ Z-Wave Plus Interface Module would remain in an action for longer than desired. This update allows the 738Z+ to return to its default state for quicker adding, editing, and deleting of Z-Wave devices and actions.